Selected pages from internal Fakta report (prepared by COWI) Key figures Outlet no. Address Power (refrigeration) MWh/year Power (lighting) MWh/year Power (misc.) MWh/year Power (total) MWh/year 201 Ejbovej 35   Bjæverskov 107 (63%) 55 (32%) 8 (5%) 170 (100%) 203 Vallekildevej 27   Hørve 121 (64%) 62 (33%) 5 (3%) 189 (100%) 204 Sct. Jørgensgade37 Kalundborg 117 (67%) 51 (30%) 5 (3%) 192 (100%) 209 Arn. Nielsens Boul. Hvidovre 102 (67%) 46 (30%) 5 (3%) 153 (100%) 217 Frederikshorgvej 18 Helsinge 87 (57%) 61 (40%) 5 (3%) 153 (100%) 223S Amagerbrogade 29   Copenhagen S 200 (62%) 112 (35%) 10 (3%) 322 (100%) 226S Hurnlebækcenteret Humlebæk 132 (70%) 51 (27%) 6 (3%) 187 (100%) 328 Njalsgade, 13   Copenhagen S 141 (71%) 54 (27%) 6 (3%) 201 (100%) 340 Hamletsgade 8   Copenhagen N 111 (63%) 61 (35%) 5 (3%) 177 (100%) 377S Banevej 1   Karise 118 (57%) F84 (40%) 5 (3%) 207 (100%) Average 123 (64%) 64 (33%) 6 (3%) 193 (100%) Industry energy analysis (18 outlets) Fakta 2001 (10 outlets) Refrigeration and freezing 64% 64%   Lighting 30% 33% Misc. 6% 3% Refrigeration figures On the basis of the 1994 industry energy analysis for supermarkets, etc., Super Køl and COWI have developed a unit termed equivalent metre. 1 equivalent refrigeration metre equals 3,000 kWh/year. The figures stated have been calculated on the basis of actual measurements previously made, but are in no way “scientific” and should be taken with some uncertainty. In theory, it is now possible to compute the expected refrigeration need using the following equivalent rates: Refrigerated display case/room Door/kWh/year or kWh/year/metre   Equivalent rates/m Refrigerated rack 3000:3000 1 Milk room (per door) 2450:3000 0.8 Freezer room (per door) 5100:3000 1.7 Freezer room, ice (per door) 6000:3000 2.0 Freezer island (own compressor) 3500:3000 1.2 Freezer island (parallel system) 2400:3000 0.8 Refrigerated island (own compressor) 1500:3000 0.5 Refrigerated island (parallel system) 900:3000 0.3 Island, ice 3000:3000 1.0 Coca-Cola 1500:3000 0.5 Example: Annual theoretical energy consumption of one milk room: 0.8 equivalent metres * 6 doors * 3000 kWh/year = 14,400 kWh a year