Assessment of DHA in self-tanning creams applied in spray booths

Figure text:
Y-akse: Particle mass (dM/dlogdp)
X-akse: Droplet size (micrometer)

Figure 8. Size distribution for particles (measured as mass) as a five-second average during spray session in a closed booth. The drops are differentiated within the area 0.5 to 20 µm. The table to the right shows the time for each average measurement.

Figure 8. Size distribution for particles (measured as mass) as a five-second average during spray session in a closed booth. The drops are differentiated within the area 0.5 to 20 µm. The table to the right shows the time for each average measurement.

 



Version 1.0 September 2006, © Danish Environmental Protection Agency