| Front page | | Contents | | Back | | Printing instructions |
Survey and health assessment of mercury in compact fluorescent lamps and straight fluorescent lamps
Table 5-2 Calculated concentrations in the breathing zone of mercury with a broken compact fluorescent lamp/straight fluorescent lamp in a room when it is assumed that only 10 % of total quantity of mercury will evaporate during the first few hours. The meaning of the green cells is discussed later.
Quantity Hg (mg) |
Air exchange (per hour) |
Room volume (m³) |
Ventilation (m³/min) |
Room conc. T = 0 min (µ/m³) |
Room conc. T = 5 min (µ/m³) |
Room conc. T = 10 min (µ/m³) |
Room conc. T = 15 min (µ/m³) |
Room conc. T = 30 min (µ/m³) |
Room conc. T = 45 min (µ/m³) |
Room conc. T = 60 min (µ/m³) |
Room conc. T = 120 min (µ/m³) |
1,2 |
0 |
2 |
0 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
60 |
1,2 |
0,6 |
2 |
0,02 |
60 |
54 |
49 |
44 |
33 |
24 |
18 |
5,4 |
1,2 |
4,2 |
2 |
0,14 |
60 |
30 |
15 |
7,3 |
0,9 |
0,1 |
0,01 |
0,000 |
1,4 |
0 |
2 |
0 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
70 |
1,4 |
0,6 |
2 |
0,02 |
70 |
63 |
57 |
52 |
38 |
28 |
21 |
6 |
1,4 |
4,2 |
2 |
0,14 |
70 |
35 |
17 |
9 |
1,0 |
0,1 |
0,02 |
0,000 |
2 |
0 |
2 |
0 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
100 |
2 |
0,6 |
2 |
0,02 |
100 |
90 |
82 |
74 |
55 |
41 |
30 |
9 |
2 |
4,2 |
2 |
0,14 |
100 |
50 |
25 |
12 |
1,5 |
0,2 |
0,02 |
0,000 |
2,5 |
0 |
2 |
0 |
125 |
125 |
125 |
125 |
125 |
125 |
125 |
125 |
2,5 |
0,6 |
2 |
0,02 |
125 |
113 |
102 |
93 |
69 |
51 |
38 |
11 |
2,5 |
4,2 |
2 |
0,14 |
125 |
62 |
31 |
15 |
1,9 |
0,2 |
0,03 |
0,000 |
3,5 |
0 |
2 |
0 |
175 |
175 |
175 |
175 |
175 |
175 |
175 |
175 |
3,5 |
0,6 |
2 |
0,02 |
175 |
158 |
143 |
130 |
96 |
71 |
53 |
16 |
3,5 |
4,2 |
2 |
0,14 |
175 |
87 |
43 |
21 |
2,6 |
0,3 |
0,04 |
0,000 |
4,9 |
0 |
2 |
0 |
245 |
245 |
245 |
245 |
245 |
245 |
245 |
245 |
4,9 |
0,6 |
2 |
0,02 |
245 |
222 |
201 |
182 |
134 |
100 |
74 |
22 |
4,9 |
4,2 |
2 |
0,14 |
245 |
122 |
60 |
30 |
3,7 |
0,4 |
0,06 |
0,000 |
5 |
0 |
2 |
0 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
250 |
5 |
0,6 |
2 |
0,02 |
250 |
226 |
205 |
185 |
137 |
102 |
75 |
23 |
5 |
4,2 |
2 |
0,14 |
250 |
124 |
62 |
31 |
3,7 |
0,5 |
0,06 |
0,000 |
7 |
0 |
2 |
0 |
350 |
350 |
350 |
350 |
350 |
350 |
350 |
350 |
7 |
0,6 |
2 |
0,02 |
350 |
317 |
287 |
259 |
192 |
142 |
105 |
32 |
7 |
4,2 |
2 |
0,14 |
350 |
174 |
86 |
43 |
5,2 |
0,6 |
0,08 |
0,000 |
8 |
0 |
2 |
0 |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
400 |
8 |
0,6 |
2 |
0,02 |
400 |
362 |
327 |
296 |
220 |
163 |
120 |
36 |
8 |
4,2 |
2 |
0,14 |
400 |
199 |
99 |
49 |
6,0 |
0,7 |
0,09 |
0,000 |
9,5 |
0 |
2 |
0 |
475 |
475 |
475 |
475 |
475 |
475 |
475 |
475 |
9,5 |
0,6 |
2 |
0,02 |
475 |
430 |
389 |
352 |
261 |
193 |
143 |
43 |
9,5 |
4,2 |
2 |
0,14 |
475 |
236 |
117 |
58 |
7,1 |
0,9 |
0,11 |
0,000 |
13 |
0 |
2 |
0 |
650 |
650 |
650 |
650 |
650 |
650 |
650 |
650 |
13 |
0,6 |
2 |
0,02 |
650 |
588 |
532 |
482 |
357 |
264 |
196 |
59 |
13 |
4,2 |
2 |
0,14 |
650 |
323 |
160 |
80 |
9,7 |
1,2 |
0,15 |
0,000 |
15 |
0 |
2 |
0 |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
750 |
15 |
0,6 |
2 |
0,02 |
750 |
679 |
614 |
556 |
412 |
305 |
226 |
68 |
15 |
4,2 |
2 |
0,14 |
750 |
372 |
185 |
92 |
11 |
1,4 |
0,2 |
0,000 |
40 |
0 |
2 |
0 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
2000 |
40 |
0,6 |
2 |
0,02 |
2000 |
1810 |
1637 |
1482 |
1098 |
813 |
602 |
181 |
40 |
4,2 |
2 |
0,14 |
2000 |
993 |
493 |
245 |
30 |
3,7 |
0,4 |
0,000 |
| Front page | | Contents | | Back | | Printing instructions |
Version 1.0 August 2010, © Danish Environmental Protection Agency
|