Table 4: Proposal for new emission factors. (Existing factors are shown in brackets)
Old designation New designation Akk.
tank.
TSP
g/GJ
PM10
g/GJ
PM2.5
g/GJ
Dioxin
ng/GJ
NMVOC
g/GJ
Benzo(a)
pyrene
g/GJ
Benzo(b)
fluoranthe
n
mg/GJ
Benzo(k)
fluoranthe
n
mg/GJ
Indeno(1,
2,3-cd)
pyrene
mg/GJ
Old stove Stoves without DS
leabel from before
approx. 1985-1990
  850
(1100)
810
(1045)
810
(990)
800 1200 250 240 150 180
New stove Stoves with DS label
from 1990-2005
  850
(1100)
810
(1045)
810
(990)
800 1000
(1200)
250 240 150 180
Modern stove Stoves complying with
Order 2008 and/or NS
  640 610
(608)
610
(576)
300 250 100 90 40 60
New modern stove Swan labelled stoves
or corresponding
foreign standard
  250
(320)
240
(304)
240
(288)
150 125 50 45 20 30
Other stove Fireplaces etc.   900
(1100)
860
(1045)
850
(990)
800 1200 250 240 150 180
Old boiler Boilers without type-
approval from before
approx. 1980
Yes 600
(1000)
570
(950)
570
(900)
500 400 130 200 100 80
    No 1200
(2000)
1140
(1900)
1140
(1800)
500 1000
(400)
650
(130)
1000
(200)
500
(100)
400
(80)
New boiler Modern boilers after
approx. 1980,
including boilers with
t
ype-approval
Yes 80
(150)
76
(143)
76
(135)
300
(50)
100
(20)
50
(40)
60
(14)
20 (8) 20
(6)
    No 160
(300)
152
(285)
152
(270)
300 250 100
(12)
120
(60)
40
(20)
40
(20)
Pellet boiler Wood pellet boiler   35 33 32 30
(50)
20 12
(15)
14
(16)
8 (10) 6 (9)

 



Version 1.0 Marts 2010, © Miljøstyrelsen.