[Front page] [Contents] [Previous] [Next]

Heavy Metals in Packagings - Check Analyses 1998

3. Results

Sample No.

Type of Sample

ppm Cr

ppm Cd

ppm Hg

ppm Pb

1

V

1820 <10 <10 150
2

V

1500 <10 <10 41
3

V

970 <10 <10 29
4

V

990 <10 <10 50
5

V

1500 <10 <10 45
6

V

1200 <10 <10 460
7

V

340 <10 <10 110
8

V

590 <10 <10 160
9

V

60 <10 <10 160
10

V

1700 <10 <10 260
11

V

1700 <10 <10 220
12

V

1300 <10 <10 100
13

V

1300 <10 <10 120
14

V

1600 <10 <10 160
15

V

1600 <10 <10 110
16

V

1400 <10 <10 100
17

V

1600 <10 <10 71
18

V

1900 <10 <10 150
19

V

1800 <10 <10 110
20

V

390 <10 <10 130
21

V

1300 <10 <10 370
22

V

1300 <10 <10 300
23

V

1300 <10 <10 300
24

V

2200 <10 <10 200
25

V

1300 <10 <10 26
26

V

1700 <10 <10 210
27

V

1200 <10 <10 78
28

V

1400 <10 <10 220
29

V

1300 <10 <10 140
30

V

74 <10 <10 64
31

V

1700 <10 <10 150
32

V

1200 <10 <10 350
33

V

1650 <10 <10 150
34

V

1700 <10 <10 200
35

V

29 <10 <10 420
36

V

600 <10 <10 170
37

V

1400 <10 <10 170
38

V

1200 <10 <10 2400
39

V

570 <10 <10 170
40

V

600 <10 <10 160
41

V

1100 <10 <10 37
42

V

1300 <10 <10 26
43

V

2100 <10 <10 180
44

V

1600 <10 <10 29
45

V

1200 <10 <10 29
46

V

300 <10 <10 110
47

V

1300 <10 <10 200
48

D

<1 * <10 <10 150 *
49

T

<10 <10 <10 50
50

T

<10 <10 <10 36
51

V

1300 <10 <10 73
52

V

1600 <10 <10 37

The results marked with *) have been found by atomic
absorption spectrometry.

The other results are average values of double determinations
by X-ray technique. Accuracy: ± 1% rel.

Types of Samples

V Wine bottles

D Tin

T Tube

[Front page] [Contents] [Previous] [Next] [Top]