Evaluation of in vitro assays for determination of estrogenic activity in the environment
TABLE 3. Comparison of key parameters for the various in vitro assays
for detection of estrogenic activity
Assay type
ER binding
Reporter gene assays
Cell
proliferation
Assay
ER binding
ER-CALUX
MVLN
Chimeric
receptor
YES
E-screen
Cells
T47D
MVLN
MCF-7
HeLa
HGELN
Yeast
MCF-7
Laboratory
requirements
Isotope
laboratory
Sterile
laboratory equipment
Cell culture
laboratory
Sterile lab.
equipment
Cell culture
Relatively
demanding
Relatively
simple
Relatively
demanding
Miniturisation/
automation
No
Yes
Yes
Yes
Costs
Relatively
expensive
Relatively
expensive
Relatively
inexpensive
Relatively
expensive
Detection of
anti-estrogens
No
Yes
Limited
Yes
Assay time
(days)
1-2
3
4
~ 3
~ 3
~ 6
Detection limita)
(ng E2/l)
272
0.1
5
1-3
0.27
LOQ for the
whole methodb)
(ng EEQ/l)
0.001c)
0.03d)
0.07-0.14
a) Detection limit not including concentration factors (see section 5.3.1).
|