Metalafgivelse til drikkevand, DEL 2

Appendix H

1 Chemical Analysis of Metal content in Water Samples

12h stagnation

Operation period: May 1999 - March 2003

Water works: Astrup, V. Gjesing, Birkerød, Regnemark

No.Test pieces
1 and 2 Stainless steel pipes, 15/13 mm, AISI 316 (Fe 70%, Cr 17%, Ni 11%, Mo 2%)
3 and 4Stainless steel pipes, 15/13 mm with pressure fittings of stainless steel, AISI 316
5 and 6Stainless steel pipe, 15/13 mm AISI 316 with pressure fittings of tin-coated copper and tin-coated gunmetal (Cu 82%, Sn 2,8%, Pb 3%, Zn 9%, Ni 2,7%)
7 and 8Galvanised steel pipes, ½", with 0,9% Pb in Zn-coating
9 and 10Galvanised steel pipes, ½", with 0,3% Pb in Zn-coating
11 and 12:Galvanised steel pipes, ½", with 0,4% Pb in Zn-coating
13 and 14Brass, valve casings and fittings, ½", respectively Cu 61%, Zn 37%, Pb 2% and Cu 60%, Zn 37%, Pb 3%.
15 and 16Brass, manifolds with plugs, 3/4", respectively Cu 63%, Zn 35%, Pb 1,3% and Cu 61%, Zn 36%, Pb 2%.
17 and 18 Dezincification resistant brass, valve casings and fittings, ½", Cu 64%, Zn 34%, Pb 2%, As 0,09%.
19 and 20Nickel-chromium plated brass, ball valve, 3/4", with nickel plated ball
21 and 22Nickel-chromium plated brass, mixing tap, 2-grips
23 and 24Nickel-chromium plated brass, mixing tap, 1-grip

Tables with analysis results of

Zinc, Zn

Copper, Cu

Lead, Pb

Cadmium, Cd

Nickel, Ni

Arsenic, As

Klik her for at se tabeller

 